Cisco catalyst 2960X-48LPD-L LAN Base Layer 2 stackable switch is comprised of 48 Ethernet 10/100/1000 ports with POE+ and 2 x 10G SFP+ uplink interfaces.
Thiết mạng Cisco 2960X WS-C2960X-48FPD-L được thiết kế để phù hợp với lớp Accees (lớp truy nhập mạng đầu cuối) với chi phí đầu tư là thấp trong dòng Switch 2960X Series. Switch Cisco WS-C2960X-48FPD-L cung cấp 48 cổng Giga 10/100/1000 Mps Base-T PoE với 02 Uplink 10GE SFP+ để kết nối đường quang Multimode hoặc Single Mode.
Thông số cơ bản:
Product Code | WS-C2960X-48LPD-L |
Enclosure Type | Rack-mountable - 1U |
Feature Set | LAN Base |
Uplink Interfaces | 2 x 10G SFP+ |
Ports | 48 x 10/100/1000 |
Available PoE Power | 370W |
Maximum stacking number | 8 |
Stack bandwidth | 80G |
Forwarding Performance | 130.9Mpps |
Switching Bandwidth | 216Gbps |
RAM | 512 MB |
Flash Memory | 128 MB |
Dimensions | 44.5 x cm x 36.8 cm x 4.5 cm |
Package Weight | 10.65 Kg |
WS-C2960X-48LPD-L Specification |
|
Enclosure type | Rack-mountable - 1U |
Ports | 48 x 10/100/1000 + 2 x 10G SFP+ |
Network management Interface | 10/100 Mbps Ethernet (RJ-45) |
Available PoE Power | 370W |
Forwarding bandwidth(Gbps) | 108Gbps |
Maximum stacking number | 8 |
Stack Bandwidth | 80 G |
Forwarding Performance | 130.9Mpps |
Switching bandwidth | 216Gbps |
Maximum active VLANs | 1023 |
MAC Address Table Size | 16K (default) |
CPU | APM86392 600MHz dual core |
RAM | 256 MB |
Flash Memory | 64 MB |
Status Indicators | Per-port status: Link integrity, disabled, activity, speed, and full duplex System status: System, RPS, Stack link status, link duplex, PoE, and link speed |
Expansion / Connectivity | |
Console ports | USB (Type-B), Ethernet (RJ-45) |
Stacking cable | Optional |
Power Redundancy | Option (PWR-RPS2300) |
Voltage range (Auto) | 110V-240V |
Power Consumption Operational | 0.48KVA |
Miscellaneous | |
Width | 17.5 Inches (44.5 cm) |
Depth | 14.5 Inches (36.8 cm) |
Height | 1.75 Inches (4.5 cm) |
Weight | 12.9 lb (5.9 Kg) |
Package Weight | 23.48 lb (10.65 Kg) |
Rack Mounting Kit | optional |
MTBF in hours | 277,960 |
Compliant Standards |
● IEEE 802.1D Spanning Tree Protocol ● IEEE 802.1p CoS Prioritization ● IEEE 802.1Q VLAN ● IEEE 802.1s ● IEEE 802.1w ● IEEE 802.1X ● IEEE 802.1ab (LLDP) ● IEEE 802.3ad ● IEEE 802.3af and IEEE 802.3at ● IEEE 802.3ah (100BASE-X single/multimode fiber only) ● IEEE 802.3x full duplex on 10BASE-T, 100BASE-TX, and 1000BASE-T ports ● IEEE 802.3 10BASE-T ● IEEE 802.3u 100BASE-TX ● IEEE 802.3ab 1000BASE-T ● IEEE 802.3z 1000BASE-X ● RMON I and II standards ● SNMP v1, v2c, and v3 ● IEEE 802.3az ● IEEE 802.1ax |
System software / license | |
System software | IOS LAN BASE |
license | NERGY-MGT-100-K9, EW-DO-100-DE |
features |
●Jumbo Frames ●VLANS ●Voice Vlan ●VTPv2 ●CDPv2 ●LLDP ●802.3ad LACP ●PVST/PVST+ ●802.1W/802.1S ●Port Fast/Uplink Fast ●port CoS Trust and Override ●Scheduling ●Priority Queuing ●Configure CoS Priority Queues ●Weighted Tail Drop ●DSCP transparency |
Network security |
●SSH, SSL and SCP ●RADIUS and TACACS+ ●SNMPv3 crypto ●802.1x ●802.1x Accounting / MIB ●802.1x w/ port security ●802.1x w/Voice VLAN ●802.1x Guest VLAN ●802.1x VLAN assignment ●802.1x MAC-Auth Bypass ●BPDU/Root Guard ●Port Security ●Private VALN Edge ●Storm Control ●Block unknown unicast and multicast ●IGMP Snooping ●IGMP Filter/Throttle |
Management and Troubleshooting |
●Auto-MDOX ●TDR ●UDLD ●IP SLA Responder ●layer 2 / IP Traceroute ●SPAN ●RSPAN ●Express Setup ●Device Manager ●Cisco Network Assistant ●Smartports + Advisor ●Troubleshooting Advisor ●Drag-and-drop Cisco IOS Upgrade ●IP Address DHCP ●Autoinstall with saved configuration ●Configuration Replace ●DHCP Auto Image Upgrade ●DHCP Port Based Allocation ●Error Disable MIB |
Environmental Ranges | |
Operating temperature up to 5000 ft (1500 m) |
23ºF to 113ºF (-5ºC to 45ºC) |
Operating temperature up to 10,000 ft (3000 m) |
23ºF to 104ºF (-5ºC to 40ºC) |
Short-term exception at sea level* |
23ºF to 131ºF (-5ºC to 55ºC) |
Short-term exception up to 5000 feet (1500 m)* |
23ºF to 122ºF (-5ºC to 50ºC) |
Short-term exception up to 10,000 feet (3000 m)* |
23ºF to 113ºF (-5ºC to 45ºC) |
Short-term exception up to 13,000 feet (4000 m)* |
23º to 104ºF (-5ºC to 40ºC) |
Storage temperature up to 15,000 feet (4573 m) |
-13º to 158ºF (-25º to 70ºC) |
Operating altitude |
Up to 10,000 Feet (Up to 3000 Meters) |
Storage altitude |
Up to 13,000 (Up to 4000 Meters) |
Operating relative humidity | 10% to 95% noncondensing |
Storage relative humidity | 10% to 95% noncondensing |
Các module quang 1G Cisco cho WS-C2960X-48LPD-L
Các module quang 10G Cisco dùng cho WS-C2960X-48LPD-L
Các module quang OEM cho WS-C2960X-48LPD-L
GLC-T | Module quang Cisco GLC-T 1000BASE-T, RJ-45 connector |
GLC-TE | Module quang Cisco GLC-TE 1000BASE-T, RJ-45 connector |
GLC-SX-MMD | Module quang Cisco GLC-SX-MMD 1000BASE-SX, MMF, DOM, 850 nm, 550m, Dual LC |
GLC-LH-SMD | Module quang Cisco GLC-LH-SMD 1000BASE-LX/LH, MMF/SMF DOM, 1310 nm, 10km, Dual LC |
GLC-EX-SMD | Module quang Cisco GLC-EX-SMD 1000BASE-EX, SMF, DOM, 1310 nm, 40km, Dual LC |
GLC-ZX-SMD | Module quang Cisco GLC-ZX-MMD 1000BASE-ZX, SMF, DOM, 1550 nm, 80km, Dual LC |
GLC-SX-MM | Module quang Cisco GLC-SX-MM 1000BASE-SX, MMF, 850 nm, 550m, Dual LC |
GLC-LH-SM | Module quang Cisco GLC-LH-SM 1000BASE-LX/LH, MMF/SMF, 1310 nm, 10km, Dual LC |
GLC-ZX-SM | Module quang Cisco GLC-ZX-SM 1000BASE-ZX, SMF, 1550 nm, 80km, Dual LC |
GLC-BX-D | Module quang Cisco GLC-BX-D 1000BASE-BX, SMF, 1490TX 1310RX, Single LC |
GLC-BX-U | Module quang Cisco GLC-BX-D 1000BASE-BX, SMF, 1310TX 1490RX, Single LC |
GLC-BX40-D-I | Module quang Cisco 1000BASE-BX40 SFP, 1550NM |
GLC-BX40-U-I | Module quang Cisco 1000BASE-BX40 SFP, 1310NM |
GLC-BX40-DA-I | Module quang Cisco 1000BASE-BX40 SFP, 1490NM |
GLC-BX80-D-I | Module quang Cisco 1000BASE-BX80 SFP, 1570NM |
GLC-BX80-U-I | Module quang Cisco 1000BASE-BX80 SFP, 1490NM |
GLC-2BX-D | Module quang Cisco GLC-2BX-D 1000BASE-BX10, SMF, 1310TX 1490RX, 2 single LC/PC |
SFP-GE-T | Module quang Cisco GLC-T 1000BASE-T, RJ-45 connector |
SFP-GE-S | Module quang CiscoSFP-GE-S 1000BASE-SX, MMF, DOM, 850 nm, 550m |
SFP-GE-L | Module quang Cisco SFP-GE-L 1000BASE-LX/LH, MMF/SMF DOM, 1300 nm, 10km, Dual LC |
SFP-GE-Z | Module quang Cisco SFP-GE-Z 1000BASE-ZX, SMF, 1550 nm, 80km, Dual LC |
GLC-SX-MM-RGD | Module quang Cisco GLC-SX-MM-RGD 1000BASE-SX, MMF, 850 nm, 550m, Dual LC, industrial |
GLC-LX-SM-RGD | Module quang Cisco GLC-LX-SM-RGD 1000BASE-LX/LH, MMF/SMF, 1300 nm, 10km, Dual LC, industrial |
GLC-ZX-SM-RGD | Module quang Cisco GLC-ZX-SM-RGD 1000BASE-ZX, SMF, 1550 nm, 80km, Dual LC, industrial |
SFP-GPON-B | Module quang SFP-GPON-B GPON Class B+ SFP OLT, 1490TX 1310RX |
SFP-GPON-C | Module quang SFP-GPON-C GPON Class C+ SFP OLT 1490TX 1310RX |
SFP-GPON-B-I | Module quang SFP-GPON-B GPON Class B+ SFP OLT, 1490TX 1310RX, industrial |
SFP-GPON-C-I | Module quang SFP-GPON-C GPON Class C+ SFP OLT 1490TX 1310RX, industrial |
Các module quang 10G Cisco dùng cho WS-C2960X-48LPD-L
SFP-10G-SR-S | 10GBASE-SR SFP Module, Enterprise-Class |
SFP-10G-SR | 10GBASE-SR SFP Module |
SFP-10G-LR-S | 10GBASE-LR SFP Module, Enterprise-Class |
SFP-10G-LRM | 10GBASE-LRM SFP Module |
SFP-10G-LR | 10GBASE-LR SFP Module |
SFP-10G-ER-S | 10GBASE-ER SFP Module, Enterprise-Class |
SFP-10G-ER | Cisco 10GBASE-ER SFP+ Module for SMF |
SFP-10G-ZR-S | 10GBASE-ZR SFP Module, Enterprise-Class |
SFP-10G-ZR | Cisco 10GBASE-ZR SFP10G Module for SMF |
SFP-10G-BXU-I= | SFP+ Bidirectional for 10km, upstream |
SFP-10G-BXD-I= | SFP+ Bidirectional for 10km, downstream |
SFP-10G-BX40U-I | SFP+ Bidirectional for 40km, upstream |
SFP-10G-BX40D-I | SFP+ Bidirectional for 40km, downstream |
SFP-10G-AOC7M | 10GBASE Active Optical SFP+ Cable, 7M |
SFP-10G-AOC5M | 10GBASE Active Optical SFP+ Cable, 5M |
SFP-10G-AOC3M | 10GBASE Active Optical SFP+ Cable, 3M |
SFP-10G-AOC2M | 10GBASE Active Optical SFP+ Cable, 2M |
SFP-10G-AOC1M | 10GBASE Active Optical SFP+ Cable, 1M |
SFP-10G-AOC10M | 10GBASE Active Optical SFP+ Cable, 10M |
Các module quang OEM cho WS-C2960X-48LPD-L
Part | Depcription |
---|---|
GLC-LH-SMD-CL | OEM GLC-LH-SMD 1000BASE-LX/LH, MMF/SMF DOM, 1310 nm, 10km, Dual LC |
GLC-SX-MMD-CL | OEM GLC-SX-MMD 1000BASE-SX, MMF, DOM, 850 nm, 550m, Dual LC |
GLC-EX-SMD-CL | OEM GLC-EX-SMD 1000BASE-EX, SMF, DOM, 1310 nm, 40km, Dual LC |
GLC-T-CL | OEM GLC-T 1000BASE-T, RJ-45 connector |
GLC-LH-SM-CL | OEM GLC-T 1000BASE-T, RJ-45 connector |
GLC-LH-SM-CL | OEM GLC-LH-SMD 1000BASE-LX/LH, MMF/SMF DOM, 1310 nm, 10km, Dual LC |
GLC-SX-MM-CL | OEM GLC-SX-MM 1000BASE-SX, MMF, 850 nm, 550m, Dual LC |
Các Stack Module, Stack dùng cho Switch Cisco C2960X – C2960XR
Part Number | Description |
C2960X-STACK | FlexStack-Plus hot-swappable stacking module |
C2960X-FIBER-STK | FlexStack-Extended Fiber stacking module |
C2960X-HYBRID-STK | FlexStack-Extended Hybrid module, with one copper and one fiber port |
CAB-STK-E-0.5M | Stacking cable with a 0.5 m length |
CAB-STK-E-1M | Stacking cable with a 1.0 m length |
CAB-STK-E-3M | Stacking cable with a 3.0 m length |